Usefulness of the paralens fluorescent microscope adaptor for the identification of mycobacteria in both field and laboratory settings.
Abstract
The presence of acid-fast bacilli (AFB) in laboratories has traditionally been demonstrated using the fluorochrome method, which requires a fluorescent microscope or the Ziehl-Neelsen (ZN) method employing light microscopy. Low sensitivity of the ZN method and high costs of fluoroscopy make the need for a more effective means of diagnosis a top priority, especially in developing countries where the burden of tuberculosis is high. The QBC ParaLens attachment (QBC Diagnostic Inc., Port Matilda, PA) is a substitute for conventional fluoroscopy in the identification of AFB. To evaluate the efficacy of the ParaLens LED (light-emitting diode) system, the authors performed a two-part study, looking at usefulness, functionality and durability in urban/rural health clinics around the world, as well as in a controlled state public health laboratory setting. In the field, the ParaLens was durable and functioned well with various power sources and lighting conditions. Results from the state laboratory indicated agreement between standard fluorescent microscopy and fluorescent microscopy using the ParaLens. This adaptor is a welcome addition to laboratories in resource-limited settings as a useful alternative to conventional fluoroscopy for detection of mycobacterial species.Citation
Open Microbiol J. 2010 Apr 30; 4:30-33ae974a485f413a2113503eed53cd6c53
10.2174/1874285801004010030
Scopus Count
Related articles
- Comparison Of Ziehl-Neelsen Based Light Microscopy With Led Fluorescent Microscopy For Tuberculosis Diagnosis: An Insight From A Limited Resource-High Burden setting.
- Authors: Noori MY, Ali F, Ali Z, Sharafat S
- Issue date: 2017 Oct-Dec
- Diagnostic performance of fluorescent light-emitting diode microscopy for tuberculous lymphadenitis in a high-burden setting.
- Authors: Abdissa K, Tadesse M, Abdella K, Bekele A, Bezabih M, Abebe G
- Issue date: 2015 Nov
- [Standardization of laboratory tests for tuberculosis and their proficiency testing].
- Authors: Abe C
- Issue date: 2003 Aug
- Comparison of Lumin LED fluorescent attachment, fluorescent microscopy and Ziehl-Neelsen for AFB diagnosis.
- Authors: Trusov A, Bumgarner R, Valijev R, Chestnova R, Talevski S, Vragoterova C, Neeley ES
- Issue date: 2009 Jul
- Comparison of the modified fluorescent method and conventional Ziehl-Neelsen method in the detection of acidfast bacilli in lymphnode aspirates.
- Authors: Annam V, Kulkarni MH, Puranik RB